PUF Panels What Thermal Ratings Matter Most

Why PUF Panels Lead in Energy Efficient Thermal Insulation

Rising energy costs are gutting margins in modern cold storage, and conventional insulation often fails to meet stricter thermal codes without inflating wall thickness. Specifying PUF panels is not just about checking an R-value box on a spec sheet; it is about guaranteeing the building envelope performs a decade down the line without thermal bridging…

Prefabricated Construction What Is Prefabricated Construction?

What Is Prefabricated Construction? A Complete Overview

Prefabricated construction shifts building from a field craft to a manufacturing discipline by producing structural components in a controlled off-site facility. The market reflects this urgency, valued at USD 175.9 billion in 2025 and projected to nearly double by 2035. Procurement officers are moving past the old “temporary building” stigma to secure the speed and…

Dry vs Cold Rooms Quick Comparison Framework

Dry vs Cold Rooms: Key Differences & Industry Applications

Most people assume dry rooms and cold rooms are interchangeable — they both control temperature, right? Wrong. One manages humidity; the other manages cold. Get the distinction wrong, and you’re looking at product spoilage, failed compliance inspections, or a HVAC system running at 110% capacity for no reason. We’ve seen it across food processing, pharma,…

Cold Storage How to Calculate the Volume of Cold Storage

How to Calculate the Volume of Cold Storage

Underestimating cold storage volume eats into profit margins faster than refrigeration costs. Most facility planners assume the external dimensions translate directly to pallet capacity, but that math ignores the physical reality of the building envelope. At RaxPanel, we factor in that a standard high-efficiency insulated panel system reduces internal clearances by roughly 200mm per wall,…

EPS R-Value EPS R-Value: Thickness, Density & ASTM C578

EPS R-Value: Thickness, Density & ASTM C578

Most spec sheets rank EPS as the weakest rigid foam per inch. That assumption costs you money. At RaxPanel, we watch buyers reach for XPS on cold storage projects without running the full cost-per-R-value calculation. The EPS R-Value lands between R-3.6 and R-4.4 per inch, and it holds that number for decades. The foam is…

Cleanroom Guide to Cleanroom Humidity Control Solutions

Guide to Cleanroom Humidity Control Solutions

Particle control defines a cleanroom on paper, but humidity control defines it in operation. If you let relative humidity drop below 40%, static charges accumulate on insulating surfaces and destroy sensitive electronics components instantly. Most ISO 8 environments maintain a strict band between 45% and 65% RH to create a conductive moisture film that bleeds…