Panel de carrocería de camión refrigerado

Refrigerated truck body panels are insulated FRP or aluminum-skinned sandwich panel systems engineered for refrigerated truck bodies, reliably maintaining internal temperatures from -25°C to +5°C for perishable transport. The outer skins use gel-coated fiberglass reinforced plastic (FRP) at 1.4-2.0mm thickness, with smooth aluminum or pre-painted steel available as alternative surfaces to match specific fleet requirements.

The polyurethane (PU) foam core delivers thermal insulation with a density of 40-45 kg/m³ and thermal conductivity of 0.022-0.024 W/(m·K), ensuring stable cold chain performance. For cost-sensitive applications, extruded polystyrene (XPS) cores are offered at 35-40 kg/m³ density with thermal conductivity of 0.027-0.034 W/(m·K), suitable for moderately insulated transport.

Standard panel thickness ranges from 50mm to 125mm, with 60mm, 80mm, and 100mm as the most common configurations for chilled and frozen applications. Panels are available in widths up to 2,700mm and custom lengths up to 10,000mm, joined by tongue-and-groove or overlapping profiles sealed with polyurethane adhesive to eliminate thermal bridging and air leakage.

These insulated panels serve frozen and chilled food distribution, pharmaceutical cold chain, perishable logistics, reefer semi-trailers, and mobile catering units. They meet ATP compliance standards, achieving Normally Insulated (IN) K-values ≤ 0.70 W/m²K and Heavily Insulated (IR) K-values ≤ 0.40 W/m²K for certified international perishable transport.

Your Trusted Manufacturer for Refrigerated Truck Body Panel

RaxPanel manufactures refrigerated truck body panels at our Hebei, China facility using continuous high-pressure vacuum lamination that bonds gel-coated FRP or aluminum skins to PU and XPS cores in a single pass. The process produces monolithic skin-to-core adhesion exceeding 100 kPa per EN 14509, eliminating the delamination risk that compromises thermal performance under road vibration and thermal cycling.

Our cold chain quality process includes K-value verification testing on production samples to confirm ATP classification compliance before shipment. With a daily production capacity exceeding 1,700 m² and exports to more than 30 countries and regions, we supply reefer body builders and fleet operators who require documented thermal performance data with every panel batch.

  • In-house high-pressure vacuum lamination with single-pass skin-to-core bonding, eliminating secondary adhesive steps and reducing delamination risk under road vibration.
  • Batch K-value testing on production samples before dispatch, with thermal performance data sheets included in every shipment for fleet operator documentation.
  • CNC trimming, routing, and edge profiling to match body-builder drawings; panels ship pre-finished and cut to exact body dimensions.
  • Panels delivered pre-finished with gel-coat or painted surfaces, CNC-trimmed to body-builder drawings for direct assembly without secondary machining on site.
Parámetro Valor
Material del revestimiento Gel-coated FRP / Aluminum / Pre-painted Steel
Espesor de Chapa 1.4-2.0 mm
Material del Núcleo PU foam / XPS
Densidad del núcleo PU: 40-45 kg/m³; XPS: 35-40 kg/m³
Conductividad térmica PU: 0.022-0.024 W/(m·K); XPS: 0.027-0.034 W/(m·K)
Rango de Espesor 50-125 mm (standard: 60, 80, 100 mm)
Max Width Up to 2,700 mm
Longitud Máxima Hasta 10.000 mm
Resistencia de adhesión > 100 kPa (EN 14509)
Sistema de Junta Tongue-and-groove / overlapping with PU adhesive
Temperature Range -25°C to +5°C
ATP Classification IN: K ≤ 0.70 W/m²K; IR: K ≤ 0.40 W/m²K
Resistencia al Fuego B1 (DIN 4102)
Accessories 304 stainless frames, EPDM seals, aluminum edge protectors





    Este sitio está protegido por reCAPTCHA y la Política de Privacidad y Términos de Servicio son aplicables.

    Refrigerated Truck Body Panel Selection Guide

    Refrigerated body panels must hold a certified thermal envelope under road vibration, thermal cycling, and daily wash-down. The specification decisions below determine whether the body passes ATP inspection and keeps operating costs low over its service life.

    Pro Tip: Match Core Type to ATP Classification
    PU core at 100 mm or above achieves IR certification (K ≤ 0.40 W/m²K) for frozen transport at -25°C. XPS at 60-80 mm suits IN classification for chilled distribution. Always verify K-values on production samples, not just design calculations, before body certification.

    1. Choosing between PU and XPS cores

    Parámetro PU Core XPS Core
    Conductividad térmica 0.022-0.024 W/(m·K) 0.027-0.034 W/(m·K)
    Densidad 40-45 kg/m³ 35-40 kg/m³
    ATP Class IR (Heavily Insulated) IN (Normally Insulated)
    Best For Frozen -25°C Chilled 0 to +5°C

    2. Selecting panel thickness for the temperature range

    For deep-frozen transport at -25°C, 100 mm or 125 mm PU panels achieve IR K-values ≤ 0.40 W/m²K. For chilled distribution between 0°C and +5°C, 60-80 mm panels meet IN requirements at ≤ 0.70 W/m²K while keeping tare weight low. Multi-temperature bodies with a movable bulkhead typically specify 80 mm walls and 100 mm roof to balance the two zones.

    3. Joint sealing and thermal bridge prevention

    Tongue-and-groove and overlapping profiles are sealed with polyurethane adhesive to eliminate thermal bridging and air infiltration at panel connections. The adhesive must remain flexible at -25°C to accommodate the differential contraction between the FRP skin and the foam core. Corner joints and door frame interfaces are the most common leak paths and should receive a continuous sealant bead during assembly.

    4. Skin material and wash-down durability

    Gel-coated FRP skins at 1.4-2.0 mm resist the alkaline detergents and high-pressure water used in daily food-transport wash-down cycles. Aluminium skins offer a brighter interior for visual inspection but dent more easily during loading. Pre-painted steel is the most economical option for exterior surfaces where impact risk is low.

    5. ATP certification and documentation

    ATP certification requires K-value testing of the complete body every six years. Panels manufactured with verified skin-to-core adhesion exceeding 100 kPa per EN 14509 and sealed joints maintain thermal performance between tests. Production batch documentation with K-value test data supports fleet operators during ATP renewal inspections.

    Preguntas Frecuentes

    What thickness do I need for frozen transport at -25°C?

    100 mm or 125 mm PU panels achieve IR K-values ≤ 0.40 W/m²K. For chilled distribution 0 to +5°C, 60-80 mm panels meet IN requirements at ≤ 0.70 W/m²K.

    ¿Cómo evita el lamido al vacío la delaminación?

    Continuous high-pressure vacuum lamination creates monolithic skin-to-core bonds exceeding 100 kPa per EN 14509, preventing delamination under thermal cycling between -25°C and ambient plus road vibration.

    ¿Se pueden reparar los paneles tras un daño por impacto?

    Los daños localizados en la capa superficial pueden lijarse y relaminarse con FRP de gel-coat a juego. Un daño en el núcleo que supere los 50 mm de diámetro requiere recortar hasta la espuma sana y fijar un tapón de reemplazo del núcleo con adhesivo de PU.

    ¿Cuál es la vida útil esperada de los paneles?

    Con el gel-coat intacto y las uniones selladas, los paneles con núcleo de PU mantienen un rendimiento térmico de clasificación ATP durante 10-15 años. La inspección periódica de los sellos de las esquinas y las juntas de las puertas previene la fuga de aire que eleva los valores K con el tiempo.

    Fabricante de Paneles Sándwich

    Custom Core & Skin • Tailored Dimensions





      Este sitio está protegido por reCAPTCHA y la Política de Privacidad y Términos de Servicio son aplicables.