16. لوحة هيكل شاحنة مبردة

ألواح جسم شاحنة التبريد هي أنظمة ألواح ساندويتش مبطنة بغلاف من FRP أو الألومنيوم، مهندسة لأجسام شاحنات التبريد، تحافظ بشكل موثوق على درجات الحرارة الداخلية من -25°C إلى +5°C لنقل المواد القابلة للتلف. تُستخدم.

The polyurethane (PU) foam core delivers thermal insulation with a density of 40-45 kg/m³ and thermal conductivity of 0.022-0.024 W/(m·K), ensuring stable cold chain performance. For cost-sensitive applications, extruded polystyrene (XPS) cores are offered at 35-40 kg/m³ density with thermal conductivity of 0.027-0.034 W/(m·K), suitable for moderately insulated transport.

Standard panel thickness ranges from 50mm to 125mm, with 60mm, 80mm, and 100mm as the most common configurations for chilled and frozen applications. Panels are available in widths up to 2,700mm and custom lengths up to 10,000mm, joined by tongue-and-groove or overlapping profiles sealed with polyurethane adhesive to eliminate thermal bridging and air leakage.

These insulated panels serve frozen and chilled food distribution, pharmaceutical cold chain, perishable logistics, reefer semi-trailers, and mobile catering units. They meet ATP compliance standards, achieving Normally Insulated (IN) K-values ≤ 0.70 W/m²K and Heavily Insulated (IR) K-values ≤ 0.40 W/m²K for certified international perishable transport.

Your Trusted Manufacturer for Refrigerated Truck Body Panel

RaxPanel manufactures refrigerated truck body panels at our Hebei, China facility using continuous high-pressure vacuum lamination that bonds gel-coated FRP or aluminum skins to PU and XPS cores in a single pass. The process produces monolithic skin-to-core adhesion exceeding 100 kPa per EN 14509, eliminating the delamination risk that compromises thermal performance under road vibration and thermal cycling.

Our cold chain quality process includes K-value verification testing on production samples to confirm ATP classification compliance before shipment. With a daily production capacity exceeding 1,700 m² and exports to more than 30 countries and regions, we supply reefer body builders and fleet operators who require documented thermal performance data with every panel batch.

  • In-house high-pressure vacuum lamination with single-pass skin-to-core bonding, eliminating secondary adhesive steps and reducing delamination risk under road vibration.
  • Batch K-value testing on production samples before dispatch, with thermal performance data sheets included in every shipment for fleet operator documentation.
  • CNC trimming, routing, and edge profiling to match body-builder drawings; panels ship pre-finished and cut to exact body dimensions.
  • Panels delivered pre-finished with gel-coat or painted surfaces, CNC-trimmed to body-builder drawings for direct assembly without secondary machining on site.
المعلمة القيمة
مادة الجلد Gel-coated FRP / Aluminum / Pre-painted Steel
Skin Thickness 1.4-2.0 mm
مادة القلب PU foam / XPS
كثافة اللب PU: 40-45 kg/m³; XPS: 35-40 kg/m³
التوصيل الحراري PU: 0.022-0.024 W/(m·K); XPS: 0.027-0.034 W/(m·K)
نطاق السمك 50-125 mm (standard: 60, 80, 100 mm)
الحد الأقصى للعرض حتى 2,700 مم
الحد الأقصى للطول حتى 10,000 مم
Adhesion Strength > 100 kPa (EN 14509)
نظام المفاصل Tongue-and-groove / overlapping with PU adhesive
Temperature Range -25°C to +5°C
ATP Classification IN: K ≤ 0.70 W/m²K; IR: K ≤ 0.40 W/m²K
مقاومة الحريق B1 (DIN 4102)
Accessories 304 stainless frames, EPDM seals, aluminum edge protectors





    هذا الموقع محمي بواسطة reCAPTCHA وسياسة الخصوصية و شروط الخدمة تنطبق.

    Refrigerated Truck Body Panel Selection Guide

    Refrigerated body panels must hold a certified thermal envelope under road vibration, thermal cycling, and daily wash-down. The specification decisions below determine whether the body passes ATP inspection and keeps operating costs low over its service life.

    Pro Tip: Match Core Type to ATP Classification
    PU core at 100 mm or above achieves IR certification (K ≤ 0.40 W/m²K) for frozen transport at -25°C. XPS at 60-80 mm suits IN classification for chilled distribution. Always verify K-values on production samples, not just design calculations, before body certification.

    1. Choosing between PU and XPS cores

    المعلمة PU Core XPS Core
    التوصيل الحراري 0.022-0.024 W/(m·K) 0.027-0.034 W/(m·K)
    الكثافة 40-45 kg/m³ 35-40 kg/m³
    ATP Class IR (Heavily Insulated) IN (Normally Insulated)
    الأفضل لـ Frozen -25°C Chilled 0 to +5°C

    2. Selecting panel thickness for the temperature range

    For deep-frozen transport at -25°C, 100 mm or 125 mm PU panels achieve IR K-values ≤ 0.40 W/m²K. For chilled distribution between 0°C and +5°C, 60-80 mm panels meet IN requirements at ≤ 0.70 W/m²K while keeping tare weight low. Multi-temperature bodies with a movable bulkhead typically specify 80 mm walls and 100 mm roof to balance the two zones.

    3. Joint sealing and thermal bridge prevention

    Tongue-and-groove and overlapping profiles are sealed with polyurethane adhesive to eliminate thermal bridging and air infiltration at panel connections. The adhesive must remain flexible at -25°C to accommodate the differential contraction between the FRP skin and the foam core. Corner joints and door frame interfaces are the most common leak paths and should receive a continuous sealant bead during assembly.

    4. Skin material and wash-down durability

    Gel-coated FRP skins at 1.4-2.0 mm resist the alkaline detergents and high-pressure water used in daily food-transport wash-down cycles. Aluminium skins offer a brighter interior for visual inspection but dent more easily during loading. Pre-painted steel is the most economical option for exterior surfaces where impact risk is low.

    5. ATP certification and documentation

    ATP certification requires K-value testing of the complete body every six years. Panels manufactured with verified skin-to-core adhesion exceeding 100 kPa per EN 14509 and sealed joints maintain thermal performance between tests. Production batch documentation with K-value test data supports fleet operators during ATP renewal inspections.

    الأسئلة الشائعة

    What thickness do I need for frozen transport at -25°C?

    100 mm or 125 mm PU panels achieve IR K-values ≤ 0.40 W/m²K. For chilled distribution 0 to +5°C, 60-80 mm panels meet IN requirements at ≤ 0.70 W/m²K.

    كيف تمنع التلاصق الفراغي الانفصال الطبقي؟

    اللصق المستمر بالضغط العالي والفراغ ينشئ روابط متكاملة بين القشرة والنواة تتجاوز 100 كيلو باسكال وفقاً للمواصفة EN 14509، مما يمنع انفصال الطبقات تحت دورات التغيّر الحراري بين -25°م ودرجة الحرارة المحيطة بالإضافة إلى اهتزازات الطرق.

    هل يمكن إصلاح الألواح بعد أضرار الاصطدام؟

    يمكن إزالة الضرر الموضعي في القشرة بالجلي وإعادة اللصق بمركب ألياف زجاجية (FRP) مغلف بطلاء جيلاتيني مطابق. أما تلف النواة الذي يتجاوز قطره 50 مم فيستوجب القطع حتى الوصول إلى الرغوة السليمة ولصق سداد نواة بديل باستخدام لاصق البولي يوريثان (PU).

    ما هو العمر التشغيلي المتوقع للألواح؟

    مع بقاء الطلاء الجيلاتيني سليماً والمفاصل محكمة، تحتفظ ألواح ذات نواة البولي يوريثان (PU) بالأداء الحراري حسب تصنيف ATP لمدة 10-15 عاماً. الفحص الدوري لخواتم الزوايا وسدادات الأبواب يمنع تسرب الهواء الذي يرفع قيم K مع مرور الوقت.

    Sandwich Panel Manufacturer

    Custom Core & Skin • Tailored Dimensions





      هذا الموقع محمي بواسطة reCAPTCHA وسياسة الخصوصية و شروط الخدمة تنطبق.