Clean room partition panels create controlled environments with precisely regulated air quality, temperature, and humidity for stringent contamination control applications.
The panels combine a polyurethane (PU) or polyisocyanurate (PIR) foam core with metal facings of pre-painted galvanized steel, stainless steel grades 304 or 316, or embossed aluminum. The dense, closed-cell core gives low heat conductivity for energy-efficient performance, while an integral tongue-and-groove system with an internal cam-lock mechanism ensures robust, airtight connections between panels.
Available in thicknesses from 50mm to 200mm and custom dimensions, these panels serve pharmaceutical manufacturing, biotechnology labs, microelectronics cleanrooms, medical device production, and food processing facilities. They construct walls, ceilings, and specialized enclosures to maintain International Organization for Standardization (ISO)-classified clean environments.
The thermal bridge-free design and airtight cam-lock system deliver superior insulation while minimizing energy loss. Smooth, non-porous surfaces inhibit bacterial growth and enable easy decontamination for international hygiene compliance. Installation utilizes the cam-lock system—panels connect via tongue-and-groove joints and lock with an Allen key, allowing vertical or horizontal assembly without on-site cutting.
Supplier of High-Performance Clean Room Partition
Cleanroom partition panels let you divide a single building into multiple controlled zones, each held to its own ISO 14644 classification and pressure cascade. RaxPanel manufactures modular partition systems that pharmaceutical, electronics, and medical-device facilities use to separate processing grades, material airlocks, and support rooms.
Each partition panel pairs a PUR or PIR core with smooth, non-porous steel or stainless steel faces, joined by a cam-lock tongue-and-groove system that locks into a continuous, airtight wall without on-site cutting. The flush interlock leaves no crevices for particulate to collect, and the modular format means partitions can be extended, reconfigured, or relocated as process layouts change.
We supply partition systems complete with aluminum floor channels, radius corner covings, ceiling transitions, and matching flush doors and windows, so every junction remains cleanable and pressure-tight. Send us your zoning plan, target classifications, and panel thickness, and we will work out a partition package that fits your facility.
| Parámetro | Valor |
|---|---|
| Material del Núcleo | CFC-free polyurethane (PU) or polyisocyanurate (PIR) foam |
| Densidad del núcleo | 40–45 kg/m³ |
| Facing Materials | Pre-painted galvanized steel, stainless steel (304/316), embossed aluminum |
| Standard Thicknesses | 50 mm, 75 mm, 100 mm, 120 mm, 150 mm, 200 mm |
| Thermal Conductivity | ≤ 0.024 W/m·K (PU/PIR foam core) |
| Sistema de Junta | Tongue-and-groove with internal cam-lock mechanism |
| Acabado superficial | Premium polyester, PVDF; available in RAL colors |
| Ancho del panel | Customizable; common standard widths include 960 mm, 1000 mm, 1120 mm |
| Longitud del panel | Custom, typically up to 12 m for shipping |
| Resistencia al Fuego | Varies by core (e.g., PIR offers higher fire resistance) |
| Resistencia a la Compresión | ≥ 160 kPa |
| Application Temperature Range | Controlled ambient cleanroom environments (typically 18–26°C); pharmaceutical, biotech, electronics, and food-processing cleanrooms |
| Installation | Modular, cam-lock system for fast assembly; vertical or horizontal installation without on-site cutting |
| Hygiene Standards | Meets international standards (e.g., FDA, EC, USDA); smooth, non-porous, easy to clean |
| Customization | Available in custom sizes, colors, and configurations |
ISO 14644 & GMP Clean Room Panel System Guide
Cleanroom sandwich panels are specifically engineered for contamination-controlled environments in pharmaceutical manufacturing, semiconductor fabrication, biotechnology labs, and medical operating suites. Built with anti-static, anti-bacterial coated steel facings or Grade 304 stainless steel bonded to Rockwool or Aluminum Honeycomb cores, these panels comply with ISO 14644-4 Class 1 to Class 9 and EU GMP Annex 1 sterility mandates.
At RaxPanel, our cleanroom panels feature double-male-female aluminum keels that interlock completely flush with 0mm surface steps. Joints are sealed with medical-grade non-outgassing silicone, eliminating ledges where dust or microbes collect and standing up to daily Vaporized Hydrogen Peroxide (VHP) sterilization.
1. Why Are Anti-Static (ESD) and Anti-Bacterial Coatings Required?
Standard building steel paint attracts airborne dust through static charge. RaxPanel cleanroom coatings maintain surface resistivity of 10⁶ to 10⁹ Ω/sq to prevent Electrostatic Discharge (ESD) damage in microelectronics, while nano-copper/silver ion additives inhibit bacterial growth by > 99.9%.
2. What Core Options Fit Cleanroom Walls vs Walk-On Ceilings?
Cleanroom core selection governs structural deflection under differential air pressure (+50 Pa) and foot-traffic maintenance loads:
3. Cómo las Puertas de Sala Limpia Integradas y los Ventanales de Doble Acristalamiento Mantienen la Presión del Aire
Las puertas de sala limpia de RaxPanel se instalan completamente a ras con los paneles de pared adyacentes en ambos lados. Los ventanales presentan acristalamiento de doble capa de vidrio templado de seguridad, relleno con nitrógeno seco y desecante interno para evitar la formación de niebla por condensación.
4. Inmunidad al Lavado Químico (VHP y 70% IPA)
- Peróxido de Hidrógeno Vaporizado (VHP): Recubrimientos de pintura HDP/PVDF especiales resisten ciclos de descontaminación con VHP en concentración 35% sin formación de ampollas en la superficie.
- Alcohol y Desinfectantes en Paño: Resistente a la limpieza continua con 70% Alcohol Isopropílico (IPA), hipoclorito de sodio y biocidas de amonio cuaternario.
5. ¿Dónde se Instalan Más Comúnmente los Sistemas de Paneles para Salas Limpias?
Zonas de procesamiento y envasado aséptico conformes a GMP UE Grados A/B/C/D.
Fabricación de obleas y laboratorios láser antiestáticos ESD seguros, ISO 5 / Clase 100.
6. Remates de Radio de Aluminio para Uniones de Pared a Piso a 90°
Para cumplir con la saneamiento GMP, todas las esquinas internas de pared a pared y de pared a piso a 90° se equipan con perfiles de cimbra cóncavos de aluminio de inserción (R50 mm), asegurando transiciones de esquinas redondeadas y fáciles de limpiar.
Frequently Asked Questions (FAQS)
1. ¿Qué clasificaciones ISO de sala limpia cumplen los paneles de sala limpia de RaxPanel?
2. ¿Por qué es obligatorio un sistema de junta a ras en las salas limpias farmacéuticas?
3. ¿Qué material de núcleo se recomienda para sistemas de techo transitable en salas limpias?
4. ¿Los recubrimientos de sala limpia de RaxPanel son resistentes al Peróxido de Hidrógeno Vaporizado (VHP)?
5. How do anti-static ESD cleanroom panels work?
6. Are cleanroom doors and windows pre-engineered to fit the panel thickness?
7. What aluminum profile accessories are supplied with cleanroom panel packages?