Panel de dormitorio para obra

Site dormitory panels are rock wool sandwich panel systems engineered for worker accommodation buildings that house large numbers of occupants over extended project durations. Designed for construction site dormitories, labor camps, and modular workforce housing, these panels deliver the acoustic privacy, thermal comfort, and ventilation performance required for healthy long-term habitation in multi-room, multi-story configurations.

The rock wool core at 80-120 kg/m³ provides sound insulation of Rw 30-35 dB between adjacent rooms, reducing noise transfer that disrupts occupant rest in high-density dormitory layouts. Thermal conductivity of 0.040-0.045 W/(m·K) maintains stable interior temperatures across seasons, supporting consistent comfort in dormitory rooms occupied 10-14 hours daily. The inorganic fiber structure is dimensionally stable under humidity cycling, preventing the moisture absorption and panel sag that degrade insulation in continuously occupied buildings.

Panels are manufactured in effective widths of 950mm and 1150mm to align with standard dormitory module planning grids, supporting corridor-access layouts with rooms on one or both sides. Thickness options from 50mm to 150mm accommodate multi-story stacking up to 3 levels, with the structural frame carrying floor live loads of 2.0-2.5 kN/m² for furnished dormitory rooms. Concealed-clip and tongue-and-groove joints create clean interior wall surfaces without exposed fixings, simplifying cleaning and maintenance in shared accommodation.

These site dormitory panels serve construction workforce camps, mining site housing, modular hospitals, resettlement projects, and emergency relief shelters. The panel system supports dormitory planning standards for minimum floor area per occupant, natural ventilation opening ratios, and corridor egress widths, with wind load resistance of 0.6-1.5 kPa for exposed site locations.

Your Trusted Manufacturer for Site Dormitory Panel

RaxPanel is a direct manufacturer of rock wool sandwich panels based in Hebei, China, supplying construction contractors and camp housing providers in over 30 countries. Our production and engineering focus addresses the habitability requirements of workforce accommodation: panel dimensions are manufactured to align with dormitory planning grids for standard room sizes and corridor widths, ventilation opening provisions are integrated into panel layouts to meet minimum air change rates for occupied rooms, and thermal performance is verified for year-round comfort in continuously inhabited buildings.

With a daily production capacity exceeding 1,700 m², RaxPanel delivers the volume required for multi-unit dormitory projects housing hundreds of workers. Batch consistency in panel thickness, joint alignment, and surface finish ensures uniform room quality across large camp deployments, with documentation packages supporting occupant building compliance submissions for project owners and regulatory authorities.

  • Panel dimensions aligned with dormitory planning grids for standard room modules and corridor layouts.
  • Ventilation provisions integrated into panel layouts meeting minimum air change rates for occupied rooms.
  • Thermal performance verified for year-round comfort in continuously inhabited dormitory buildings.
  • Multi-unit project delivery with batch consistency documentation for camp housing compliance submissions.
Parámetro Valor
Material del revestimiento Color-coated galvanized steel
Espesor de Chapa 0.5 mm
Material del Núcleo Rock Wool (stone wool)
Densidad del núcleo 80-120 kg/m³
Total Panel Thickness 50 / 75 / 100 / 120 / 150 mm
Effective Width 950 / 1150 mm
Conductividad térmica 0.040-0.045 W/(m·K)
Sound Insulation Rw 30-35 dB
Fire Rating A1 non-combustible (EN 13501-1 / EN 13501-1)
Resistencia al Fuego EI30 at 50mm; EI60 at 80mm; EI120 at 100mm
Wind Load Resistance 0.6-1.5 kPa
Floor Live Load 2.0-2.5 kN/m²
Max Stacking 3 stories (with structural steel frame)
Joint Type Tongue & Groove / Concealed Clip
Process Continuous high-pressure lamination
Aplicaciones Site dormitories, labor camps, workforce housing, modular hospitals
Service Life 15+ years





    Este sitio está protegido por reCAPTCHA y la Política de Privacidad y Términos de Servicio son aplicables.

    Site Dormitory Panel Buying Guide & FAQ

    A site dormitory has to house people safely and comfortably, then be taken down and moved when the project ends. That dual demand — liveable accommodation that is also demountable — drives every material choice, from fire performance for sleeping occupants to the connections that let the building be re-erected elsewhere. The guide below covers the decisions contractors and camp operators make when specifying insulated panels for workforce dormitories.

    Pro Tip: Treat Fire Performance as Non-Negotiable
    Dormitories are sleeping occupancy, so a fire starts with people asleep and unable to react quickly. Specify a core with a verified EN 13501-1 reaction-to-fire class and low smoke production, and confirm the rating on the datasheet rather than accepting an untested claim.

    1. What insulation level keeps occupants comfortable?

    Comfort comes from a stable interior temperature and warm internal surfaces, not just from heating power. A well-insulated envelope reduces the heating and cooling load and keeps the wall and ceiling surfaces close to room temperature, which is what occupants actually feel. The table gives typical starting points for a PU core of 40–45 kg/m³.

    Climate Typical Core Approx. U-value
    Mild / temperate 75–100 mm PU 0.29–0.22 W/m²·K
    Hot or cold extremes 100–120 mm PU 0.22–0.18 W/m²·K
    High fire-sensitivity spec Mineral wool 80–100 mm 0.50–0.43 W/m²·K

    2. Which core is appropriate for sleeping accommodation?

    Fire reaction is assessed under EN 13501-1. PIR cores reach class B-s1,d0, combining strong insulation with low smoke and no flaming droplets, which is why they are widely used in site accommodation. Mineral wool is non-combustible at A2-s1,d0 and is specified where the project or local code demands the highest fire performance. EPS is combustible and is generally avoided for sleeping units, where the consequence of fire is greatest.

    Life-safety note
    Smoke production (the s rating) matters as much as combustibility in a dormitory, because smoke is what incapacitates sleeping occupants first. A class with s1 smoke production gives more escape time than one with heavier smoke, even at the same combustibility class.

    3. ¿Cómo se despliegan y reubican las unidades de residencia?

    La viabilidad económica de una residencia panelizada se basa en la reutilización. Las unidades están diseñadas para embalaje plano en el transporte y montaje rápido con una pequeña cuadrilla y tiempo mínimo de grúa, utilizando marcos atornillados y conexiones de panel con cierre por camilla o lengüeta y ranura. Estas mismas conexiones permiten desmontar el edificio al final del proyecto, trasladarlo al siguiente emplazamiento y volverlo a montar, a menudo varias veces durante su vida útil. Especificar conexiones robustas y reutilizables desde el inicio protege ese valor residual.

    4. ¿Cómo se gestiona la condensación en un edificio fuertemente ocupado?

    Una residencia completa genera una gran carga de humedad por la respiración, el lavado y la cocina. Si esa humedad se condensa en superficies frías, el resultado son humedad, moho y un mal aire interior. Un envolente aislado continuo mantiene las superficies interiores por encima del punto de rocío para que no se forme condensación, mientras que la ventilación mecánica expulsa el aire húmedo. El aislamiento y la ventilación trabajan juntos; uno sin el otro sigue dejando un interior húmedo.

    5. ¿Qué aislamiento acústico deben proporcionar las habitaciones?

    Los ocupantes descansan entre turnos, por lo que la separación acústica entre habitaciones y el ruido exterior del emplazamiento afectan directamente al bienestar. El núcleo de lana mineral en particular ofrece un buen aislamiento acústico aéreo debido a su densidad y estructura fibrosa, mientras que los paneles de PU con juntas selladas limitan las vías laterales por las que el sonido puede propagarse. La especificación de tabiques debe adaptarse a la exposición al ruido del emplazamiento y al patrón de ocupación.

    Preguntas Frecuentes

    ¿Qué nivel de aislamiento mantiene una residencia de obra cómoda durante todo el año?

    Para alojamiento ocupado en climas templados, los paneles de PU de 75–100 mm ofrecen valores U de aproximadamente 0,29–0,22 W/m²·K, lo que mantiene una temperatura interior confortable con calefacción y refrigeración modestas. Los emplazamientos más cálidos o más fríos se benefician de 100–120 mm para reducir el coste de funcionamiento y mejorar la comodidad.

    ¿Qué núcleo es el más seguro para el alojamiento de dormitorios?

    Dado que los dormitorios son ocupación para dormir, el comportamiento ante el fuego es crucial. Los núcleos de PIR alcanzan la clase B-s1,d0 según EN 13501-1, con baja emisión de humo y sin goteo inflamable, mientras que la lana mineral es incombustible en A2-s1,d0 y se adapta a los requisitos de incendio más estrictos en emplazamientos. El EPS es combustible y generalmente se evita en unidades de dormitorio.

    ¿Con qué rapidez se puede desplegar y reubicar un campamento de dormitorios?

    Las unidades de dormitorio panelizadas están diseñadas para un montaje rápido y reutilización. Los kits de embalaje plano se montan con una pequeña cuadrilla y maquinaria mínima, y las conexiones atornilladas o de cierre por camilla permiten desmontar, trasladar y volver a montar todo el edificio en el siguiente emplazamiento, lo que es la base económica del alojamiento temporal de la fuerza laboral.

    ¿Cómo se controla la condensación en un dormitorio fuertemente ocupado?

    Los ocupantes generan una gran carga de humedad por la respiración, el lavado y la cocina. Un envolente aislado continuo mantiene las superficies interiores por encima del punto de rocío para que la humedad no se condense en las paredes, mientras que la ventilación mecánica elimina el aire húmedo. Se necesitan ambos: el aislamiento sin ventilación sigue dejando un interior húmedo y propenso al moho.

    Fabricante de Paneles Sándwich

    Custom Core & Skin • Tailored Dimensions





      Este sitio está protegido por reCAPTCHA y la Política de Privacidad y Términos de Servicio son aplicables.