Industrial Partition Panel

Industrial partition panels are steel-faced sandwich components that divide interior floor space in factories, warehouses, and processing facilities without masonry construction. Pre-painted galvanized steel skins (0.4-0.8 mm) bond to a PU foam or rock wool core, and concealed tongue-and-groove camlock joints join panels edge-to-edge with hidden fasteners, producing a flush wall surface that requires no plastering, taping, or painting.

Each panel integrates structural rigidity, thermal insulation, and finished surface in a single component. A partition line that would require metal stud framing, boarding, insulation batts, and two coats of paint over three to five days is completed in a single shift with no wet trades, no drying time, and no dust generation in adjacent occupied production areas.

Panels are available in thicknesses from 50 mm to 200 mm with an effective width of 1,000 mm and custom lengths up to 11,800 mm. PU cores provide thermal conductivity of 0.022-0.024 W/(m·K) for cold storage and climate-controlled zones; rock wool cores at 100-150 kg/m³ provide non-combustible classification for fire-rated compartmentation in high-hazard industrial areas.

Your Trusted Manufacturer for Industrial Partition Panel

RaxPanel produces industrial partition panels in Hebei, China, where the camlock joint profile receives particular manufacturing attention. Unlike exterior wall panels where joints are hidden behind weather flashings, partition panel joints are visible at arm’s length under warehouse lighting. The tongue-and-groove camlock geometry is roll-formed to a tolerance of plus or minus 0.3 mm on the hook engagement surface, and every production batch is test-assembled on a jig to confirm that panels lock flush without force or visible step between faces.

For PU-cored panels, foam metering accuracy directly affects panel flatness and dimensional stability. Our mixing head dispenses polyol and isocyanate at a fixed ratio with closed-loop flow monitoring; density variation across the panel width is held within plus or minus 2 kg/m³ of the 40 kg/m³ target. Panels cure in a heated press at 40-50 degrees Celsius for 15-20 minutes before trimming, ensuring complete polymerization and stable dimensions at shipping.

Panels are cut to project-specific lengths and bundled by wall line with installation-sequence labeling. For orders requiring door openings, window headers, or service penetrations, these features are CNC-machined before packing so the site crew assembles complete rooms without on-site cutting or measuring.

Parameter Value
Skin Material Pre-painted Galvanized Steel / Aluminum / Stainless Steel
Skin Thickness 0.4-0.8 mm
Core Material PU / PIR / Rock Wool
Core Density PU: 40 kg/m³; Rock Wool: 100-150 kg/m³
Thermal Conductivity PU: 0.022-0.024 W/(m·K); Rock Wool: 0.040-0.044 W/(m·K)
Thickness Range 50-200 mm (standard: 50, 75, 100 mm)
Effective Width 1,000 mm (option: 1,150 mm)
Max Length 11,800 mm
Joint System Tongue-and-groove camlock / concealed fastener
U-value (PU core) 0.39 (50 mm); 0.29 (75 mm); 0.23 (100 mm); 0.19 (125 mm)
Acoustic Insulation 25-30 dB (PU); 30-35 dB (Rock Wool)
Fire Rating A (Rock Wool); B1 (PIR); B-s2,d0 (PU) per EN 13501-1
Fire Resistance EI15-EI120 (Rock Wool per EN 13501-2)
Panel Weight 11-14 kg/m² (depending on thickness)
Coating Type PE / SMP / HDP / PVDF



    Industrial Partition Panel Engineering Guide: Core Selection, Camlock Joint Design & Cold Storage Integration

    Industrial partition walls serve a different engineering purpose from exterior cladding or office fit-out systems. They must withstand forklift impact, resist chemical splash, maintain temperature differentials between adjacent production zones, and allow rapid reconfiguration as manufacturing layouts change. The specification decisions that matter most are core material selection (which governs both thermal and fire performance), joint geometry (which determines airtightness and surface continuity), and panel gauge (which sets impact resistance and maximum unsupported height).

    1. Core Material Selection for Industrial Environments

    PU foam at 40 kg/m³ with thermal conductivity of 0.022-0.024 W/(m·K) is the default choice for ambient-temperature partitions and cold storage rooms where thermal efficiency per unit thickness is the priority. A 100 mm PU panel achieves U = 0.23 W/m²·K, sufficient for most chilled storage applications (0 to +5 degrees Celsius). For freezer rooms below -18 degrees Celsius, 150-200 mm thickness prevents condensation on the warm-side face. Rock wool cores at 100-150 kg/m³ are specified where fire compartmentation is mandated: they achieve EI60 to EI120 fire resistance per EN 13501-2, dividing high-hazard production areas from escape routes and adjacent occupancies.

    2. Camlock Joint Engineering and Airtightness

    The tongue-and-groove camlock joint uses a rotating hook mechanism embedded in the panel edge that draws adjacent panels together with approximately 2 kN of clamping force per lock. This compression deforms the EPDM gasket strip in the groove, creating an airtight seal without external fasteners. For cold storage applications, airtightness is critical: even a 1 mm gap along a 10 m joint line admits enough humid air to cause ice formation on the cold face. Camlock joints achieve air permeability below 0.5 m³/h·m² at 50 Pa pressure differential when properly engaged.

    3. Impact Resistance and Skin Gauge Selection

    Industrial environments expose partition walls to trolley impact, pallet contact, and vibration from adjacent machinery. Skin gauge selection follows the exposure severity: 0.4 mm steel suits office partitions and light assembly areas; 0.5-0.6 mm is standard for warehouse zoning and production halls; 0.8 mm with stainless steel facing is specified for food processing washdown zones and areas subject to frequent mechanical contact. For high-impact zones (loading docks, forklift corridors), add steel angle protection rails at 400-800 mm height on the traffic face.

    4. Cold Storage Partition Design

    Partitions separating cold rooms from ambient production areas must address three failure modes: thermal bridging at floor and ceiling connections, vapor drive from the warm humid side into the cold core, and ice lens formation if moisture reaches the cold face. PU core panels with camlock joints and factory-applied vapor barrier film on the warm-side face address all three. Floor connections use an insulated curb detail (50 mm PU upstand) to break the thermal bridge at the slab junction. Ceiling connections terminate in a sealed head track with compressible gasket.

    5. Modular Reconfiguration and Demountability

    Camlock partition panels are demountable without damage: the hook mechanism releases with a quarter-turn tool, panels separate cleanly, and the gasket strip is replaced for reinstallation. This allows production layouts to adapt to new product lines, seasonal volume changes, or tenant reconfiguration with near-zero material waste. A 50 m partition line can be demounted and reinstalled in a new configuration within two working days, compared to three to four weeks for masonry demolition and rebuild.

    Frequently Asked Questions

    1. What is the maximum unsupported height for an industrial partition wall?
    Standard 100 mm panels with 0.5 mm steel skins span floor-to-ceiling heights up to 4.0 m when fixed in floor and head channels. For heights between 4.0 m and 6.0 m, specify 150 mm panels with 0.6 mm skins and add a horizontal mid-rail at half height. Above 6.0 m, a structural steel sub-frame with panel infill is the appropriate solution. Lateral load capacity (push load from personnel or equipment contact) governs the deflection limit at span/150.
    2. How do partition panels perform in food processing washdown environments?
    With stainless steel or food-grade PVC-laminated skins and sealed camlock joints, panels withstand daily high-pressure washdown (up to 80 degrees Celsius water at 1 MPa) without degradation. The non-porous metal faces resist bacterial colonization, and the flush joint geometry eliminates crevices where organic matter could accumulate. Floor junctions use a coved stainless steel base channel with silicone seal to prevent standing water ingress at the panel base.
    3. Can electrical conduits and piping be routed through partition panels?
    Individual conduits (up to 25 mm diameter) pass through the core via drilled holes sealed with expanding foam at both faces. For multiple cable runs or pipework, a service cavity is created by adding a secondary skin layer on battens to one face, providing a 40-60 mm chase. Heavy pipework (above 50 mm diameter or carrying hot fluids) requires independent support from the building structure rather than loading the panel. All core penetrations must be sealed to maintain thermal and acoustic continuity.
    4. What is the installation speed compared to traditional blockwork partitions?
    A two-person crew installs 40-60 m² of partition per shift including track fixing, panel engagement, and trim installation. Equivalent blockwork construction (laying, plastering, drying, painting) requires 8-12 m² per mason per day plus 3-5 days drying between coats. For a 500 m² partition package, composite panels complete in 5-6 working days versus 4-6 weeks for masonry, with no drying delays and no dust generation in adjacent production areas.
    5. How are door frames and openings integrated into partition walls?
    Door openings are formed by factory-cut header panels and jamb trim pieces that frame the opening to the exact door size. The door frame (steel or aluminum) bolts through the panel skins into a concealed timber or steel reinforcement block embedded in the core during manufacture. This eliminates on-site cutting and ensures the frame is plumb and rigid. Sliding door tracks mount to a reinforced head panel with embedded steel channel rated for the door weight.

    Sandwich Panel Manufacturer

    Custom Core & Skin • Tailored Dimensions