Acoustic Partition Panel

Acoustic partition panels are sound-insulated sandwich components designed to block noise transmission between interior spaces while absorbing reverberant energy within the source room. Pre-painted galvanized steel skins (0.5-0.8 mm) enclose a rock wool core, with the room-facing skin micro-perforated to expose the fibrous core to incident sound waves, converting the panel from a pure barrier into a combined absorber-insulator system.

The micro-perforated inner facing (over 28% open area) allows sound energy to enter the rock wool core where randomly oriented basalt fibers dissipate it as heat. This achieves a noise reduction coefficient (NRC) of 0.80 or higher, simultaneously reducing reverberation time in the source room and limiting transmitted noise to adjacent spaces. Solid-faced panels on the receiving side provide mass-law sound reflection for maximum transmission loss.

Panels are available in thicknesses from 50 mm to 200 mm with an effective width of 1,000 mm and custom lengths up to 12,000 mm. Tongue-and-groove joints sealed with acoustic sealant eliminate flanking paths at panel connections, preserving the rated sound insulation performance across the full partition area including joints, perimeter, and penetrations.

Your Trusted Manufacturer for Acoustic Partition Panel

RaxPanel manufactures acoustic partition panels in Hebei, China, where the perforation process receives dedicated tooling attention. The micro-perforated inner face is punched on a CNC turret press with hardened tooling that produces clean, burr-free holes at consistent pitch. Perforation open area is verified by optical measurement on samples from each coil, because even a 3% deviation from the specified 28% open area shifts the absorption frequency response and degrades NRC performance below the rated value.

Rock wool core density is graded by application: 85-100 kg/m³ for general acoustic partitions where cost efficiency is prioritized, and 120-150 kg/m³ for critical installations (recording studios, cinema auditoriums) where low-frequency absorption below 250 Hz is required. Higher density increases the flow resistivity of the fiber matrix, extending effective absorption to lower octave bands. Each density grade is produced on a separate lamination run to avoid cross-contamination of fiber orientation.

Before shipping, sample panels from each production batch are assembled into a test rig and subjected to impedance tube measurement (per ISO 10534-2) to confirm the absorption coefficient curve matches the specified performance. Panels are packed with the perforated faces protected by adhesive film to prevent transport damage that would alter the open area ratio.

Parameter Value
Skin Material Pre-painted Galvanized Steel (micro-perforated inner face)
Skin Thickness 0.5-0.8 mm
Perforation Ratio > 28% open area (inner face)
Core Material Rock Wool / Mineral Wool
Core Density 85-150 kg/m³
Thermal Conductivity 0.040-0.045 W/(m·K)
Thickness Range 50-200 mm (standard: 50, 75, 100 mm)
Effective Width 1,000 mm
Max Length 12,000 mm
STC Rating 35-50 dB (thickness-dependent)
NRC (Sound Absorption) ≥ 0.80 (perforated face)
Joint System Tongue-and-groove with acoustic sealant
Fire Rating A1 non-combustible (EN 13501-1)
Melting Temperature > 1,000°C



    Acoustic Partition Panel Engineering Guide: STC vs NRC, Frequency-Dependent Design & Flanking Control

    Acoustic partition specification requires understanding two distinct performance metrics that are often confused: Sound Transmission Class (STC), which measures how much sound the partition blocks from passing through to the adjacent room, and Noise Reduction Coefficient (NRC), which measures how much sound the panel surface absorbs within the source room to reduce reverberation. A panel can score highly on one metric and poorly on the other. Effective acoustic design addresses both simultaneously.

    1. STC Rating: What Each Level Achieves in Practice

    STC is a single-number rating derived from transmission loss measurements across 125-4000 Hz. Practical interpretation: STC 25-30 allows loud speech to be heard and understood through the wall; STC 35-40 blocks loud speech to inaudibility but transmits bass frequencies and mechanical vibration; STC 45-50 renders even amplified music and industrial noise substantially inaudible. Rock wool core panels at 75 mm achieve STC 35-42 dB; 100 mm panels reach STC 40-47 dB. For STC above 50, a double-leaf construction (two panel rows with a 50-100 mm air gap) is required, as mass-law physics limits single-leaf performance regardless of thickness.

    2. NRC and Frequency-Dependent Absorption

    NRC is the arithmetic average of absorption coefficients at 250, 500, 1000, and 2000 Hz. A micro-perforated facing with rock wool core achieves NRC 0.80+, meaning 80% of incident mid-frequency sound energy is absorbed rather than reflected. However, absorption drops at low frequencies: a 50 mm panel absorbs well above 500 Hz but provides limited absorption at 125-250 Hz where machinery rumble and bass energy concentrate. For low-frequency control, specify 100-150 mm panels with 120-150 kg/m³ core density, which extends effective absorption down to 200 Hz.

    3. Flanking Path Control: The Weak Link in Acoustic Design

    A partition achieving STC 47 in laboratory testing may deliver only STC 35-38 on-site if flanking paths exist. Sound bypasses the partition through: unsealed perimeter gaps (floor track, head channel, wall jambs), service penetrations (conduits, ducts, pipework), the ceiling void above (if the partition stops at a suspended ceiling rather than extending to the structural soffit), and the floor slab (vibration transmission through the structure). Each unsealed gap of 1 mm width along a 10 m joint can reduce effective STC by 5-10 dB. Acoustic sealant at all perimeters, flexible collars at penetrations, and full-height partitions extending to the soffit are mandatory for achieving rated performance.

    4. Room-Within-Room Construction for Critical Applications

    Recording studios, broadcast rooms, and audiometric testing chambers require STC 55+ which exceeds single-leaf panel capability. The solution is room-within-room construction: an inner shell of acoustic panels is built on resilient mounts or neoprene pads, structurally isolated from the outer building shell. The air gap between inner and outer shells (minimum 100 mm) provides additional transmission loss through decoupling. Panel joints in the inner shell are sealed with non-hardening acoustic mastic, and all services enter through flexible connections that break vibration paths.

    5. Installation Sequence for Verified Acoustic Performance

    Acoustic partitions must be installed after all services (HVAC ducts, electrical conduits, plumbing) are in place, because retrofitting penetrations after panel installation compromises the sealed envelope. The sequence is: fix floor and head channels with neoprene isolation strips; install panels with acoustic sealant in every joint; seal perimeter gaps with non-hardening mastic; install service penetrations with flexible grommets; apply perimeter caulk bead at floor, ceiling, and wall junctions. Post-installation verification by on-site sound level measurement confirms the achieved STC matches the design target.

    Frequently Asked Questions

    1. What is the difference between STC and Rw, and which applies to my project?
    STC (Sound Transmission Class) is the North American single-number rating per ASTM E413; Rw (Weighted Sound Reduction Index) is the European equivalent per ISO 717-1. They use different reference curves and frequency ranges, so values are not directly interchangeable, though numerically similar (STC 45 is approximately Rw 44-46 dB). Specify the rating system that matches your project’s governing building code and acoustic consultant’s methodology. Our test data is available in both formats.
    2. Does the micro-perforated facing reduce the panel’s sound insulation (STC)?
    The perforated face slightly reduces mass-law transmission loss at the perforated side (approximately 1-2 dB) because the open area reduces the effective surface mass. However, the overall partition STC is governed by the weaker of the two faces plus the core absorption. In practice, a panel with one perforated face and one solid face achieves within 1-2 dB of a dual-solid-face panel while gaining NRC 0.80+ absorption on the room side. For maximum STC, orient the solid face toward the noise source and the perforated face toward the receiving room.
    3. How much does core density affect acoustic performance?
    Core density primarily affects low-frequency absorption and flow resistivity. At 85-100 kg/m³, the panel absorbs effectively above 500 Hz with NRC 0.75-0.80. At 120-150 kg/m³, absorption extends to 200-250 Hz with NRC 0.85-0.95, making it suitable for generator rooms and bass-heavy industrial noise. For STC (transmission loss), core density has minimal effect above 80 kg/m³ because transmission loss is dominated by face mass and panel thickness rather than core properties.
    4. Can these panels be used as external walls or are they interior-only?
    The micro-perforated facing is designed for interior use where the perforations are protected from weather. For external wall applications requiring acoustic performance (such as plant room enclosures or generator housings), specify solid-face panels with weather-resistant PVDF coating on the exterior and micro-perforated facing on the interior. The solid exterior face provides weather protection while the interior perforated face maintains absorption. Joint details use external-grade sealant and drip flashings at horizontal joints.
    5. What on-site testing verifies achieved acoustic performance after installation?
    Post-installation verification uses a sound level meter with pink noise source per ISO 16283-1 (field measurement of building element sound insulation). A loudspeaker generates calibrated pink noise in the source room; the receiving room level is measured with the source on and off to calculate the achieved DnT,w (normalized level difference). If the measured value falls below the design target, the most common causes are unsealed perimeter gaps, service penetrations without flexible collars, or flanking through the ceiling void. Remedial sealing typically recovers 5-10 dB of lost performance.

    Sandwich Panel Manufacturer

    Custom Core & Skin • Tailored Dimensions